//***************************************************************************** // // pwm.c - API for the PWM modules // // Copyright (c) 2005-2017 Texas Instruments Incorporated. All rights reserved. // Software License Agreement // // Redistribution and use in source and binary forms, with or without // modification, are permitted provided that the following conditions // are met: // // Redistributions of source code must retain the above copyright // notice, this list of conditions and the following disclaimer. // // Redistributions in binary form must reproduce the above copyright // notice, this list of conditions and the following disclaimer in the // documentation and/or other materials provided with the // distribution. // // Neither the name of Texas Instruments Incorporated nor the names of // its contributors may be used to endorse or promote products derived // from this software without specific prior written permission. // // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS // "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT // LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR // A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT // OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, // SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT // LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, // DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT // (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE // OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. // // This is part of revision 2.1.4.178 of the Tiva Peripheral Driver Library. // //***************************************************************************** //***************************************************************************** // //! \addtogroup pwm_api //! @{ // //***************************************************************************** #include #include #include "inc/hw_ints.h" #include "inc/hw_memmap.h" #include "inc/hw_pwm.h" #include "inc/hw_sysctl.h" #include "inc/hw_types.h" #include "driverlib/debug.h" #include "driverlib/interrupt.h" #include "driverlib/pwm.h" //***************************************************************************** // // Misc macros for manipulating the encoded generator and output defines used // by the API. // //***************************************************************************** #define PWM_GEN_BADDR(_mod_, _gen_) \ ((_mod_) + (_gen_)) #define PWM_GEN_EXT_BADDR(_mod_, _gen_) \ ((_mod_) + PWM_GEN_EXT_0 + \ ((_gen_) - PWM_GEN_0) * 2) #define PWM_OUT_BADDR(_mod_, _out_) \ ((_mod_) + ((_out_) & 0xFFFFFFC0)) #define PWM_IS_OUTPUT_ODD(_out_) \ ((_out_) & 0x00000001) //***************************************************************************** // //! \internal //! Checks a PWM generator number. //! //! \param ui32Gen is the generator number. //! //! This function determines if a PWM generator number is valid. //! //! \return Returnes \b true if the generator number is valid and \b false //! otherwise. // //***************************************************************************** #ifdef DEBUG static bool _PWMGenValid(uint32_t ui32Gen) { return((ui32Gen == PWM_GEN_0) || (ui32Gen == PWM_GEN_1) || (ui32Gen == PWM_GEN_2) || (ui32Gen == PWM_GEN_3)); } #endif //***************************************************************************** // //! \internal //! Checks a PWM output number. //! //! \param ui32PWMOut is the output number. //! //! This function determines if a PWM output number is valid. //! //! \return Returns \b true if the output number is valid and \b false //! otherwise. // //***************************************************************************** #ifdef DEBUG static bool _PWMOutValid(uint32_t ui32PWMOut) { return((ui32PWMOut == PWM_OUT_0) || (ui32PWMOut == PWM_OUT_1) || (ui32PWMOut == PWM_OUT_2) || (ui32PWMOut == PWM_OUT_3) || (ui32PWMOut == PWM_OUT_4) || (ui32PWMOut == PWM_OUT_5) || (ui32PWMOut == PWM_OUT_6) || (ui32PWMOut == PWM_OUT_7)); } #endif //***************************************************************************** // //! Configures a PWM generator. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to configure. This parameter must be //! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32Config is the configuration for the PWM generator. //! //! This function is used to set the mode of operation for a PWM generator. //! The counting mode, synchronization mode, and debug behavior are all //! configured. After configuration, the generator is left in the disabled //! state. //! //! A PWM generator can count in two different modes: count down mode or count //! up/down mode. In count down mode, it counts from a value down to zero, //! and then resets to the preset value, producing left-aligned PWM //! signals (that is, the rising edge of the two PWM signals produced by the //! generator occur at the same time). In count up/down mode, it counts up //! from zero to the preset value, counts back down to zero, and then repeats //! the process, producing center-aligned PWM signals (that is, //! the middle of the high/low period of the PWM signals produced by the //! generator occurs at the same time). //! //! When the PWM generator parameters (period and pulse width) are modified, //! their effect on the output PWM signals can be delayed. In synchronous //! mode, the parameter updates are not applied until a synchronization event //! occurs. This mode allows multiple parameters to be modified and take //! effect simultaneously, instead of one at a time. Additionally, parameters //! to multiple PWM generators in synchronous mode can be updated //! simultaneously, allowing them to be treated as if they were a unified //! generator. In non-synchronous mode, the parameter updates are not delayed //! until a synchronization event. In either mode, the parameter updates only //! occur when the counter is at zero to help prevent oddly formed PWM signals //! during the update (that is, a PWM pulse that is too short or too long). //! //! The PWM generator can either pause or continue running when the processor //! is stopped via the debugger. If configured to pause, it continues to //! count until it reaches zero, at which point it pauses until the //! processor is restarted. If configured to continue running, it keeps //! counting as if nothing had happened. //! //! The \e ui32Config parameter contains the desired configuration. It is the //! logical OR of the following: //! //! - \b PWM_GEN_MODE_DOWN or \b PWM_GEN_MODE_UP_DOWN to specify the counting //! mode //! - \b PWM_GEN_MODE_SYNC or \b PWM_GEN_MODE_NO_SYNC to specify the counter //! load and comparator update synchronization mode //! - \b PWM_GEN_MODE_DBG_RUN or \b PWM_GEN_MODE_DBG_STOP to specify the debug //! behavior //! - \b PWM_GEN_MODE_GEN_NO_SYNC, \b PWM_GEN_MODE_GEN_SYNC_LOCAL, or //! \b PWM_GEN_MODE_GEN_SYNC_GLOBAL to specify the update synchronization //! mode for generator counting mode changes //! - \b PWM_GEN_MODE_DB_NO_SYNC, \b PWM_GEN_MODE_DB_SYNC_LOCAL, or //! \b PWM_GEN_MODE_DB_SYNC_GLOBAL to specify the deadband parameter //! synchronization mode //! - \b PWM_GEN_MODE_FAULT_LATCHED or \b PWM_GEN_MODE_FAULT_UNLATCHED to //! specify whether fault conditions are latched or not //! - \b PWM_GEN_MODE_FAULT_MINPER or \b PWM_GEN_MODE_FAULT_NO_MINPER to //! specify whether minimum fault period support is required //! - \b PWM_GEN_MODE_FAULT_EXT or \b PWM_GEN_MODE_FAULT_LEGACY to specify //! whether extended fault source selection support is enabled or not //! //! Setting \b PWM_GEN_MODE_FAULT_MINPER allows an application to set the //! minimum duration of a PWM fault signal. Faults are signaled for at //! least this time even if the external fault pin deasserts earlier. Care //! should be taken when using this mode because during the fault signal //! period, the fault interrupt from the PWM generator remains asserted. The //! fault interrupt handler may, therefore, reenter immediately if it exits //! prior to expiration of the fault timer. //! //! \note Changes to the counter mode affect the period of the PWM signals //! produced. PWMGenPeriodSet() and PWMPulseWidthSet() should be called after //! any changes to the counter mode of a generator. //! //! \return None. // //***************************************************************************** void PWMGenConfigure(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Config) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Compute the generator's base address. // ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen); // // Change the global configuration of the generator. // HWREG(ui32Gen + PWM_O_X_CTL) = ((HWREG(ui32Gen + PWM_O_X_CTL) & ~(PWM_X_CTL_MODE | PWM_X_CTL_DEBUG | PWM_X_CTL_LATCH | PWM_X_CTL_MINFLTPER | PWM_X_CTL_FLTSRC | PWM_X_CTL_DBFALLUPD_M | PWM_X_CTL_DBRISEUPD_M | PWM_X_CTL_DBCTLUPD_M | PWM_X_CTL_GENBUPD_M | PWM_X_CTL_GENAUPD_M | PWM_X_CTL_LOADUPD | PWM_X_CTL_CMPAUPD | PWM_X_CTL_CMPBUPD)) | ui32Config); // // Set the individual PWM generator controls. // if(ui32Config & PWM_X_CTL_MODE) { // // In up/down count mode, set the signal high on up count comparison // and low on down count comparison (that is, center align the // signals). // HWREG(ui32Gen + PWM_O_X_GENA) = (PWM_X_GENA_ACTCMPAU_ONE | PWM_X_GENA_ACTCMPAD_ZERO); HWREG(ui32Gen + PWM_O_X_GENB) = (PWM_X_GENB_ACTCMPBU_ONE | PWM_X_GENB_ACTCMPBD_ZERO); } else { // // In down count mode, set the signal high on load and low on count // comparison (that is, left align the signals). // HWREG(ui32Gen + PWM_O_X_GENA) = (PWM_X_GENA_ACTLOAD_ONE | PWM_X_GENA_ACTCMPAD_ZERO); HWREG(ui32Gen + PWM_O_X_GENB) = (PWM_X_GENB_ACTLOAD_ONE | PWM_X_GENB_ACTCMPBD_ZERO); } } //***************************************************************************** // //! Sets the period of a PWM generator. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to be modified. This parameter must be //! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32Period specifies the period of PWM generator output, measured //! in clock ticks. //! //! This function sets the period of the specified PWM generator block, where //! the period of the generator block is defined as the number of PWM clock //! ticks between pulses on the generator block zero signal. //! //! \note Any subsequent calls made to this function before an update occurs //! cause the previous values to be overwritten. //! //! \return None. // //***************************************************************************** void PWMGenPeriodSet(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Period) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Compute the generator's base address. // ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen); // // Set the reload register based on the mode. // if(HWREG(ui32Gen + PWM_O_X_CTL) & PWM_X_CTL_MODE) { // // In up/down count mode, set the reload register to half the requested // period. // ASSERT((ui32Period / 2) < 65536); HWREG(ui32Gen + PWM_O_X_LOAD) = ui32Period / 2; } else { // // In down count mode, set the reload register to the requested period // minus one. // ASSERT((ui32Period <= 65536) && (ui32Period != 0)); HWREG(ui32Gen + PWM_O_X_LOAD) = ui32Period - 1; } } //***************************************************************************** // //! Gets the period of a PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to query. This parameter must be one //! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! //! This function gets the period of the specified PWM generator block. The //! period of the generator block is defined as the number of PWM clock ticks //! between pulses on the generator block zero signal. //! //! If the update of the counter for the specified PWM generator has yet //! to be completed, the value returned may not be the active period. The //! value returned is the programmed period, measured in PWM clock ticks. //! //! \return Returns the programmed period of the specified generator block //! in PWM clock ticks. // //***************************************************************************** uint32_t PWMGenPeriodGet(uint32_t ui32Base, uint32_t ui32Gen) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Compute the generator's base address. // ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen); // // Figure out the counter mode. // if(HWREG(ui32Gen + PWM_O_X_CTL) & PWM_X_CTL_MODE) { // // The period is twice the reload register value. // return(HWREG(ui32Gen + PWM_O_X_LOAD) * 2); } else { // // The period is the reload register value plus one. // return(HWREG(ui32Gen + PWM_O_X_LOAD) + 1); } } //***************************************************************************** // //! Enables the timer/counter for a PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to be enabled. This parameter must be //! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! //! This function allows the PWM clock to drive the timer/counter for the //! specified generator block. //! //! \return None. // //***************************************************************************** void PWMGenEnable(uint32_t ui32Base, uint32_t ui32Gen) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Enable the PWM generator. // HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_CTL) |= PWM_X_CTL_ENABLE; } //***************************************************************************** // //! Disables the timer/counter for a PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to be disabled. This parameter must be //! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! //! This function blocks the PWM clock from driving the timer/counter for the //! specified generator block. //! //! \return None. // //***************************************************************************** void PWMGenDisable(uint32_t ui32Base, uint32_t ui32Gen) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Disable the PWM generator. // HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_CTL) &= ~(PWM_X_CTL_ENABLE); } //***************************************************************************** // //! Sets the pulse width for the specified PWM output. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32PWMOut is the PWM output to modify. This parameter must be one //! of \b PWM_OUT_0, \b PWM_OUT_1, \b PWM_OUT_2, \b PWM_OUT_3, \b PWM_OUT_4, //! \b PWM_OUT_5, \b PWM_OUT_6, or \b PWM_OUT_7. //! \param ui32Width specifies the width of the positive portion of the pulse. //! //! This function sets the pulse width for the specified PWM output, where the //! pulse width is defined as the number of PWM clock ticks. //! //! \note Any subsequent calls made to this function before an update occurs //! cause the previous values to be overwritten. //! //! \return None. // //***************************************************************************** void PWMPulseWidthSet(uint32_t ui32Base, uint32_t ui32PWMOut, uint32_t ui32Width) { uint32_t ui32GenBase, ui32Reg; // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMOutValid(ui32PWMOut)); // // Compute the generator's base address. // ui32GenBase = PWM_OUT_BADDR(ui32Base, ui32PWMOut); // // If the counter is in up/down count mode, divide the width by two. // if(HWREG(ui32GenBase + PWM_O_X_CTL) & PWM_X_CTL_MODE) { ui32Width /= 2; } // // Get the period. // ui32Reg = HWREG(ui32GenBase + PWM_O_X_LOAD); // // Make sure the width is not too large. // ASSERT(ui32Width < ui32Reg); // // Compute the compare value. // ui32Reg = ui32Reg - ui32Width; // // Write to the appropriate registers. // if(PWM_IS_OUTPUT_ODD(ui32PWMOut)) { HWREG(ui32GenBase + PWM_O_X_CMPB) = ui32Reg; } else { HWREG(ui32GenBase + PWM_O_X_CMPA) = ui32Reg; } } //***************************************************************************** // //! Gets the pulse width of a PWM output. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32PWMOut is the PWM output to query. This parameter must be one //! of \b PWM_OUT_0, \b PWM_OUT_1, \b PWM_OUT_2, \b PWM_OUT_3, \b PWM_OUT_4, //! \b PWM_OUT_5, \b PWM_OUT_6, or \b PWM_OUT_7. //! //! This function gets the currently programmed pulse width for the specified //! PWM output. If the update of the comparator for the specified output has //! yet to be completed, the value returned may not be the active pulse width. //! The value returned is the programmed pulse width, measured in PWM clock //! ticks. //! //! \return Returns the width of the pulse in PWM clock ticks. // //***************************************************************************** uint32_t PWMPulseWidthGet(uint32_t ui32Base, uint32_t ui32PWMOut) { uint32_t ui32GenBase, ui32Reg, ui32Load; // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMOutValid(ui32PWMOut)); // // Compute the generator's base address. // ui32GenBase = PWM_OUT_BADDR(ui32Base, ui32PWMOut); // // Then compute the pulse width. If mode is UpDown, set // width = (load - compare) * 2. Otherwise, set width = load - compare. // ui32Load = HWREG(ui32GenBase + PWM_O_X_LOAD); if(PWM_IS_OUTPUT_ODD(ui32PWMOut)) { ui32Reg = HWREG(ui32GenBase + PWM_O_X_CMPB); } else { ui32Reg = HWREG(ui32GenBase + PWM_O_X_CMPA); } ui32Reg = ui32Load - ui32Reg; // // If in up/down count mode, double the pulse width. // if(HWREG(ui32GenBase + PWM_O_X_CTL) & PWM_X_CTL_MODE) { ui32Reg = ui32Reg * 2; } // // Return the pulse width. // return(ui32Reg); } //***************************************************************************** // //! Enables the PWM dead band output and sets the dead band delays. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to modify. This parameter must be one //! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui16Rise specifies the width of delay from the rising edge. //! \param ui16Fall specifies the width of delay from the falling edge. //! //! This function sets the dead bands for the specified PWM generator, where //! the dead bands are defined as the number of \b PWM clock ticks from the //! rising or falling edge of the generator's \b OutA signal. Note that this //! function causes the coupling of \b OutB to \b OutA. //! //! \return None. // //***************************************************************************** void PWMDeadBandEnable(uint32_t ui32Base, uint32_t ui32Gen, uint16_t ui16Rise, uint16_t ui16Fall) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT(ui16Rise < 4096); ASSERT(ui16Fall < 4096); // // Compute the generator's base address. // ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen); // // Write the dead band delay values. // HWREG(ui32Gen + PWM_O_X_DBRISE) = ui16Rise; HWREG(ui32Gen + PWM_O_X_DBFALL) = ui16Fall; // // Enable the deadband functionality. // HWREG(ui32Gen + PWM_O_X_DBCTL) |= PWM_X_DBCTL_ENABLE; } //***************************************************************************** // //! Disables the PWM dead band output. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to modify. This parameter must be one //! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! //! This function disables the dead band mode for the specified PWM generator. //! Doing so decouples the \b OutA and \b OutB signals. //! //! \return None. // //***************************************************************************** void PWMDeadBandDisable(uint32_t ui32Base, uint32_t ui32Gen) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Disable the deadband functionality. // HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_DBCTL) &= ~(PWM_X_DBCTL_ENABLE); } //***************************************************************************** // //! Synchronizes all pending updates. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32GenBits are the PWM generator blocks to be updated. This //! parameter must be the logical OR of any of \b PWM_GEN_0_BIT, //! \b PWM_GEN_1_BIT, \b PWM_GEN_2_BIT, or \b PWM_GEN_3_BIT. //! //! For the selected PWM generators, this function causes all queued updates to //! the period or pulse width to be applied the next time the corresponding //! counter becomes zero. //! //! \return None. // //***************************************************************************** void PWMSyncUpdate(uint32_t ui32Base, uint32_t ui32GenBits) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(!(ui32GenBits & ~(PWM_GEN_0_BIT | PWM_GEN_1_BIT | PWM_GEN_2_BIT | PWM_GEN_3_BIT))); // // Synchronize pending PWM register changes. // HWREG(ui32Base + PWM_O_CTL) = ui32GenBits; } //***************************************************************************** // //! Synchronizes the counters in one or multiple PWM generator blocks. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32GenBits are the PWM generator blocks to be synchronized. This //! parameter must be the logical OR of any of \b PWM_GEN_0_BIT, //! \b PWM_GEN_1_BIT, \b PWM_GEN_2_BIT, or \b PWM_GEN_3_BIT. //! //! For the selected PWM module, this function synchronizes the time base of //! the generator blocks by causing the specified generator counters to be //! reset to zero. //! //! \return None. // //***************************************************************************** void PWMSyncTimeBase(uint32_t ui32Base, uint32_t ui32GenBits) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(!(ui32GenBits & ~(PWM_GEN_0_BIT | PWM_GEN_1_BIT | PWM_GEN_2_BIT | PWM_GEN_3_BIT))); // // Synchronize the counters in the specified generators by writing to the // module's synchronization register. // HWREG(ui32Base + PWM_O_SYNC) = ui32GenBits; } //***************************************************************************** // //! Enables or disables PWM outputs. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter //! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT, //! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT, //! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT. //! \param bEnable determines if the signal is enabled or disabled. //! //! This function enables or disables the selected PWM outputs. The outputs //! are selected using the parameter \e ui32PWMOutBits. The parameter \e //! bEnable determines the state of the selected outputs. If \e bEnable is //! \b true, then the selected PWM outputs are enabled, or placed in the active //! state. If \e bEnable is \b false, then the selected outputs are disabled //! or placed in the inactive state. //! //! \return None. // //***************************************************************************** void PWMOutputState(uint32_t ui32Base, uint32_t ui32PWMOutBits, bool bEnable) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT | PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT | PWM_OUT_6_BIT | PWM_OUT_7_BIT))); // // Read the module's ENABLE output control register and set or clear the // requested bits. // if(bEnable == true) { HWREG(ui32Base + PWM_O_ENABLE) |= ui32PWMOutBits; } else { HWREG(ui32Base + PWM_O_ENABLE) &= ~(ui32PWMOutBits); } } //***************************************************************************** // //! Selects the inversion mode for PWM outputs. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter //! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT, //! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT, //! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT. //! \param bInvert determines if the signal is inverted or passed through. //! //! This function is used to select the inversion mode for the selected PWM //! outputs. The outputs are selected using the parameter \e ui32PWMOutBits. //! The parameter \e bInvert determines the inversion mode for the selected //! outputs. If \e bInvert is \b true, this function causes the specified //! PWM output signals to be inverted or made active low. If \e bInvert is //! \b false, the specified outputs are passed through as is or made active //! high. //! //! \return None. // //***************************************************************************** void PWMOutputInvert(uint32_t ui32Base, uint32_t ui32PWMOutBits, bool bInvert) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT | PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT | PWM_OUT_6_BIT | PWM_OUT_7_BIT))); // // Read the module's INVERT output control register and set or clear the // requested bits. // if(bInvert == true) { HWREG(ui32Base + PWM_O_INVERT) |= ui32PWMOutBits; } else { HWREG(ui32Base + PWM_O_INVERT) &= ~(ui32PWMOutBits); } } //***************************************************************************** // //! Specifies the level of PWM outputs suppressed in response to a fault //! condition. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter //! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT, //! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT, //! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT. //! \param bDriveHigh determines if the signal is driven high or low during an //! active fault condition. //! //! This function determines whether a PWM output pin that is suppressed in //! response to a fault condition is driven high or low. The affected outputs //! are selected using the parameter \e ui32PWMOutBits. The parameter //! \e bDriveHigh determines the output level for the pins identified by //! \e ui32PWMOutBits. If \e bDriveHigh is \b true then the selected outputs //! are driven high when a fault is detected. If it is \e false, the pins are //! driven low. //! //! In a fault condition, pins which have not been configured to be suppressed //! via a call to PWMOutputFault() are unaffected by this function. //! //! \note This function is available only on devices which support extended //! PWM fault handling. //! //! \return None. // //***************************************************************************** void PWMOutputFaultLevel(uint32_t ui32Base, uint32_t ui32PWMOutBits, bool bDriveHigh) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT | PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT | PWM_OUT_6_BIT | PWM_OUT_7_BIT))); // // Read the module's FAULT output control register and set or clear the // requested bits. // if(bDriveHigh == true) { HWREG(ui32Base + PWM_O_FAULTVAL) |= ui32PWMOutBits; } else { HWREG(ui32Base + PWM_O_FAULTVAL) &= ~(ui32PWMOutBits); } } //***************************************************************************** // //! Specifies the state of PWM outputs in response to a fault condition. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter //! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT, //! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT, //! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT. //! \param bFaultSuppress determines if the signal is suppressed or passed //! through during an active fault condition. //! //! This function sets the fault handling characteristics of the selected PWM //! outputs. The outputs are selected using the parameter \e ui32PWMOutBits. //! The parameter \e bFaultSuppress determines the fault handling //! characteristics for the selected outputs. If \e bFaultSuppress is \b true, //! then the selected outputs are made inactive. If \e bFaultSuppress is //! \b false, then the selected outputs are unaffected by the detected fault. //! //! On devices supporting extended PWM fault handling, the state the affected //! output pins are driven to can be configured with PWMOutputFaultLevel(). If //! not configured, or if the device does not support extended PWM fault //! handling, affected outputs are driven low on a fault condition. //! //! \return None. // //***************************************************************************** void PWMOutputFault(uint32_t ui32Base, uint32_t ui32PWMOutBits, bool bFaultSuppress) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT | PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT | PWM_OUT_6_BIT | PWM_OUT_7_BIT))); // // Read the module's FAULT output control register and set or clear the // requested bits. // if(bFaultSuppress == true) { HWREG(ui32Base + PWM_O_FAULT) |= ui32PWMOutBits; } else { HWREG(ui32Base + PWM_O_FAULT) &= ~(ui32PWMOutBits); } } //***************************************************************************** // //! Gets the PWM generator interrupt number. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator in question. This parameter must be //! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! //! This function returns the interrupt number of the corresponding PWM //! generator. //! //! \return Returns the interrupt number. // //***************************************************************************** static uint32_t _PWMGenIntNumberGet(uint32_t ui32Base, uint32_t ui32Gen) { // // Determine the generator and PWM module in question. // switch(ui32Base + ui32Gen) { // // The first PWM generator in the first PWM module. // case PWM0_BASE + PWM_GEN_0: { if(CLASS_IS_TM4C123) { return(INT_PWM0_0_TM4C123); } else if(CLASS_IS_TM4C129) { return(INT_PWM0_0_TM4C129); } else { return(0); } } // // The second PWM generator in the first PWM module. // case PWM0_BASE + PWM_GEN_1: { if(CLASS_IS_TM4C129) { return(INT_PWM0_1_TM4C129); } else { return(0); } } // // The third PWM generator in the first PWM module. // case PWM0_BASE + PWM_GEN_2: { if(CLASS_IS_TM4C129) { return(INT_PWM0_2_TM4C129); } else { return(0); } } // // The fourth PWM generator in the first PWM module. // case PWM0_BASE + PWM_GEN_3: { if(CLASS_IS_TM4C129) { return(INT_PWM0_3_TM4C129); } else { return(0); } } // // The first PWM generator in the second PWM module. // case PWM1_BASE + PWM_GEN_0: { if(CLASS_IS_TM4C123) { return(INT_PWM1_0_TM4C123); } else { return(0); } } // // The first PWM generator in the second PWM module. // case PWM1_BASE + PWM_GEN_1: { if(CLASS_IS_TM4C123) { return(INT_PWM1_1_TM4C123); } else { return(0); } } // // The first PWM generator in the second PWM module. // case PWM1_BASE + PWM_GEN_2: { if(CLASS_IS_TM4C123) { return(INT_PWM1_2_TM4C123); } else { return(0); } } // // The first PWM generator in the second PWM module. // case PWM1_BASE + PWM_GEN_3: { if(CLASS_IS_TM4C123) { return(INT_PWM1_3_TM4C123); } else { return(0); } } // // An unknown PWM module/generator was specified. // default: { return(0); } } } //***************************************************************************** // //! Registers an interrupt handler for the specified PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator in question. This parameter must be //! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! \param pfnIntHandler is a pointer to the function to be called when the PWM //! generator interrupt occurs. //! //! This function ensures that the interrupt handler specified by //! \e pfnIntHandler is called when an interrupt is detected for the specified //! PWM generator block. This function also enables the corresponding //! PWM generator interrupt in the interrupt controller; individual generator //! interrupts and interrupt sources must be enabled with PWMIntEnable() and //! PWMGenIntTrigEnable(). //! //! \sa IntRegister() for important information about registering interrupt //! handlers. //! //! \return None. // //***************************************************************************** void PWMGenIntRegister(uint32_t ui32Base, uint32_t ui32Gen, void (*pfnIntHandler)(void)) { uint32_t ui32Int; // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Get the interrupt number associated with the specified generator. // ui32Int = _PWMGenIntNumberGet(ui32Base, ui32Gen); ASSERT(ui32Int != 0); // // Register the interrupt handler. // IntRegister(ui32Int, pfnIntHandler); // // Enable the PWMx interrupt. // IntEnable(ui32Int); } //***************************************************************************** // //! Removes an interrupt handler for the specified PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator in question. This parameter must be //! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! //! This function unregisters the interrupt handler for the specified //! PWM generator block. This function also disables the corresponding //! PWM generator interrupt in the interrupt controller; individual generator //! interrupts and interrupt sources must be disabled with PWMIntDisable() and //! PWMGenIntTrigDisable(). //! //! \sa IntRegister() for important information about registering interrupt //! handlers. //! //! \return None. // //***************************************************************************** void PWMGenIntUnregister(uint32_t ui32Base, uint32_t ui32Gen) { uint32_t ui32Int; // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Get the interrupt number associated with the specified generator. // ui32Int = _PWMGenIntNumberGet(ui32Base, ui32Gen); ASSERT(ui32Int != 0); // // Disable the PWMx interrupt. // IntDisable(ui32Int); // // Unregister the interrupt handler. // IntUnregister(ui32Int); } //***************************************************************************** // //! Gets the PWM fault interrupt number. //! //! \param ui32Base is the base address of the PWM module. //! //! This function returns the fault interrupt number of the corresponding //! PWM module. //! //! \return Returns the interrupt number. // //***************************************************************************** static uint32_t _PWMFaultIntNumberGet(uint32_t ui32Base) { // // Return the fault interrupt number. // if(CLASS_IS_TM4C123) { return((ui32Base == PWM0_BASE) ? INT_PWM0_FAULT_TM4C123 : INT_PWM1_FAULT_TM4C123); } else if(CLASS_IS_TM4C129) { return((ui32Base == PWM0_BASE) ? INT_PWM0_FAULT_TM4C129 : 0); } else { return(0); } } //***************************************************************************** // //! Registers an interrupt handler for a fault condition detected in a PWM //! module. //! //! \param ui32Base is the base address of the PWM module. //! \param pfnIntHandler is a pointer to the function to be called when the PWM //! fault interrupt occurs. //! //! This function ensures that the interrupt handler specified by //! \e pfnIntHandler is called when a fault interrupt is detected for the //! selected PWM module. This function also enables the PWM fault //! interrupt in the NVIC; the PWM fault interrupt must also be enabled at the //! module level using PWMIntEnable(). //! //! \sa IntRegister() for important information about registering interrupt //! handlers. //! //! \return None. // //***************************************************************************** void PWMFaultIntRegister(uint32_t ui32Base, void (*pfnIntHandler)(void)) { uint32_t ui32Int; // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); // // Get the interrupt number associated with the specified module. // ui32Int = _PWMFaultIntNumberGet(ui32Base); ASSERT(ui32Int != 0); // // Register the interrupt handler, returning an error if one occurs. // IntRegister(ui32Int, pfnIntHandler); // // Enable the PWM fault interrupt. // IntEnable(ui32Int); } //***************************************************************************** // //! Removes the PWM fault condition interrupt handler. //! //! \param ui32Base is the base address of the PWM module. //! //! This function removes the interrupt handler for a PWM fault interrupt //! from the selected PWM module. This function also disables the PWM //! fault interrupt in the NVIC; the PWM fault interrupt must also be disabled //! at the module level using PWMIntDisable(). //! //! \sa IntRegister() for important information about registering interrupt //! handlers. //! //! \return None. // //***************************************************************************** void PWMFaultIntUnregister(uint32_t ui32Base) { uint32_t ui32Int; // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); // // Get the interrupt number associated with the specified module. // ui32Int = _PWMFaultIntNumberGet(ui32Base); ASSERT(ui32Int != 0); // // Disable the PWM fault interrupt. // IntDisable(ui32Int); // // Unregister the interrupt handler, returning an error if one occurs. // IntUnregister(ui32Int); } //***************************************************************************** // //! Enables interrupts and triggers for the specified PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to have interrupts and triggers //! enabled. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1, //! \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32IntTrig specifies the interrupts and triggers to be enabled. //! //! This function unmasks the specified interrupt(s) and trigger(s) by setting //! the specified bits of the interrupt/trigger enable register for the //! specified PWM generator. The \e ui32IntTrig parameter is the logical OR of //! \b PWM_INT_CNT_ZERO, \b PWM_INT_CNT_LOAD, \b PWM_INT_CNT_AU, //! \b PWM_INT_CNT_AD, \b PWM_INT_CNT_BU, \b PWM_INT_CNT_BD, //! \b PWM_TR_CNT_ZERO, \b PWM_TR_CNT_LOAD, \b PWM_TR_CNT_AU, \b PWM_TR_CNT_AD, //! \b PWM_TR_CNT_BU, or \b PWM_TR_CNT_BD. //! //! \return None. // //***************************************************************************** void PWMGenIntTrigEnable(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32IntTrig) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT((ui32IntTrig & ~(PWM_INT_CNT_ZERO | PWM_INT_CNT_LOAD | PWM_INT_CNT_AU | PWM_INT_CNT_AD | PWM_INT_CNT_BU | PWM_INT_CNT_BD | PWM_TR_CNT_ZERO | PWM_TR_CNT_LOAD | PWM_TR_CNT_AU | PWM_TR_CNT_AD | PWM_TR_CNT_BU | PWM_TR_CNT_BD)) == 0); // // Enable the specified interrupts/triggers. // HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_INTEN) |= ui32IntTrig; } //***************************************************************************** // //! Disables interrupts for the specified PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to have interrupts and triggers //! disabled. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1, //! \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32IntTrig specifies the interrupts and triggers to be disabled. //! //! This function masks the specified interrupt(s) and trigger(s) by clearing //! the specified bits of the interrupt/trigger enable register for the //! specified PWM generator. The \e ui32IntTrig parameter is the logical OR of //! \b PWM_INT_CNT_ZERO, \b PWM_INT_CNT_LOAD, \b PWM_INT_CNT_AU, //! \b PWM_INT_CNT_AD, \b PWM_INT_CNT_BU, \b PWM_INT_CNT_BD, //! \b PWM_TR_CNT_ZERO, \b PWM_TR_CNT_LOAD, \b PWM_TR_CNT_AU, \b PWM_TR_CNT_AD, //! \b PWM_TR_CNT_BU, or \b PWM_TR_CNT_BD. //! //! \return None. // //***************************************************************************** void PWMGenIntTrigDisable(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32IntTrig) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT((ui32IntTrig & ~(PWM_INT_CNT_ZERO | PWM_INT_CNT_LOAD | PWM_INT_CNT_AU | PWM_INT_CNT_AD | PWM_INT_CNT_BU | PWM_INT_CNT_BD | PWM_TR_CNT_ZERO | PWM_TR_CNT_LOAD | PWM_TR_CNT_AU | PWM_TR_CNT_AD | PWM_TR_CNT_BU | PWM_TR_CNT_BD)) == 0); // // Disable the specified interrupts/triggers. // HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_INTEN) &= ~(ui32IntTrig); } //***************************************************************************** // //! Gets interrupt status for the specified PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to query. This parameter must be one //! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! \param bMasked specifies whether masked or raw interrupt status is //! returned. //! //! If \e bMasked is set as \b true, then the masked interrupt status is //! returned; otherwise, the raw interrupt status is returned. //! //! \return Returns the contents of the interrupt status register or the //! contents of the raw interrupt status register for the specified //! PWM generator. // //***************************************************************************** uint32_t PWMGenIntStatus(uint32_t ui32Base, uint32_t ui32Gen, bool bMasked) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); // // Compute the generator's base address. // ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen); // // Read and return the specified generator's raw or enabled interrupt // status. // if(bMasked == true) { return(HWREG(ui32Gen + PWM_O_X_ISC)); } else { return(HWREG(ui32Gen + PWM_O_X_RIS)); } } //***************************************************************************** // //! Clears the specified interrupt(s) for the specified PWM generator block. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator to query. This parameter must be one //! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32Ints specifies the interrupts to be cleared. //! //! This function clears the specified interrupt(s) by writing a 1 to the //! specified bits of the interrupt status register for the specified PWM //! generator. The \e ui32Ints parameter is the logical OR of //! \b PWM_INT_CNT_ZERO, \b PWM_INT_CNT_LOAD, \b PWM_INT_CNT_AU, //! \b PWM_INT_CNT_AD, \b PWM_INT_CNT_BU, or \b PWM_INT_CNT_BD. //! //! \note Because there is a write buffer in the Cortex-M processor, it may //! take several clock cycles before the interrupt source is actually cleared. //! Therefore, it is recommended that the interrupt source be cleared early in //! the interrupt handler (as opposed to the very last action) to avoid //! returning from the interrupt handler before the interrupt source is //! actually cleared. Failure to do so may result in the interrupt handler //! being immediately reentered (because the interrupt controller still sees //! the interrupt source asserted). //! //! \return None. // //***************************************************************************** void PWMGenIntClear(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Ints) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT((ui32Ints & ~(PWM_INT_CNT_ZERO | PWM_INT_CNT_LOAD | PWM_INT_CNT_AU | PWM_INT_CNT_AD | PWM_INT_CNT_BU | PWM_INT_CNT_BD)) == 0); // // Clear the requested interrupts by writing ones to the specified bit // of the module's interrupt enable register. // HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_ISC) = ui32Ints; } //***************************************************************************** // //! Enables generator and fault interrupts for a PWM module. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32GenFault contains the interrupts to be enabled. This parameter //! must be a logical OR of any of \b PWM_INT_GEN_0, \b PWM_INT_GEN_1, //! \b PWM_INT_GEN_2, \b PWM_INT_GEN_3, \b PWM_INT_FAULT0, \b PWM_INT_FAULT1, //! \b PWM_INT_FAULT2, or \b PWM_INT_FAULT3. //! //! This function unmasks the specified interrupt(s) by setting the specified //! bits of the interrupt enable register for the selected PWM module. //! //! \return None. // //***************************************************************************** void PWMIntEnable(uint32_t ui32Base, uint32_t ui32GenFault) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT((ui32GenFault & ~(PWM_INT_GEN_0 | PWM_INT_GEN_1 | PWM_INT_GEN_2 | PWM_INT_GEN_3 | PWM_INT_FAULT0 | PWM_INT_FAULT1 | PWM_INT_FAULT2 | PWM_INT_FAULT3)) == 0); // // Read the module's interrupt enable register and enable interrupts // for the specified PWM generators. // HWREG(ui32Base + PWM_O_INTEN) |= ui32GenFault; } //***************************************************************************** // //! Disables generator and fault interrupts for a PWM module. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32GenFault contains the interrupts to be disabled. This parameter //! must be a logical OR of any of \b PWM_INT_GEN_0, \b PWM_INT_GEN_1, //! \b PWM_INT_GEN_2, \b PWM_INT_GEN_3, \b PWM_INT_FAULT0, \b PWM_INT_FAULT1, //! \b PWM_INT_FAULT2, or \b PWM_INT_FAULT3. //! //! This function masks the specified interrupt(s) by clearing the specified //! bits of the interrupt enable register for the selected PWM module. //! //! \return None. // //***************************************************************************** void PWMIntDisable(uint32_t ui32Base, uint32_t ui32GenFault) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT((ui32GenFault & ~(PWM_INT_GEN_0 | PWM_INT_GEN_1 | PWM_INT_GEN_2 | PWM_INT_GEN_3 | PWM_INT_FAULT0 | PWM_INT_FAULT1 | PWM_INT_FAULT2 | PWM_INT_FAULT3)) == 0); // // Read the module's interrupt enable register and disable interrupts // for the specified PWM generators. // HWREG(ui32Base + PWM_O_INTEN) &= ~(ui32GenFault); } //***************************************************************************** // //! Clears the fault interrupt for a PWM module. //! //! \param ui32Base is the base address of the PWM module. //! //! This function clears the fault interrupt by writing to the appropriate bit //! of the interrupt status register for the selected PWM module. //! //! This function clears only the FAULT0 interrupt and is retained for //! backwards compatibility. It is recommended that PWMFaultIntClearExt() be //! used instead because it supports all fault interrupts supported on devices //! with and without extended PWM fault handling support. //! //! \note Because there is a write buffer in the Cortex-M processor, it may //! take several clock cycles before the interrupt source is actually cleared. //! Therefore, it is recommended that the interrupt source be cleared early in //! the interrupt handler (as opposed to the very last action) to avoid //! returning from the interrupt handler before the interrupt source is //! actually cleared. Failure to do so may result in the interrupt handler //! being immediately reentered (because the interrupt controller still sees //! the interrupt source asserted). //! //! \return None. // //***************************************************************************** void PWMFaultIntClear(uint32_t ui32Base) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); // // Write the only writeable bit in the module's interrupt register. // HWREG(ui32Base + PWM_O_ISC) = PWM_ISC_INTFAULT0; } //***************************************************************************** // //! Gets the interrupt status for a PWM module. //! //! \param ui32Base is the base address of the PWM module. //! \param bMasked specifies whether masked or raw interrupt status is //! returned. //! //! If \e bMasked is set as \b true, then the masked interrupt status is //! returned; otherwise, the raw interrupt status is returned. //! //! \return The current interrupt status, enumerated as a bit field of //! \b PWM_INT_GEN_0, \b PWM_INT_GEN_1, \b PWM_INT_GEN_2, \b PWM_INT_GEN_3, //! \b PWM_INT_FAULT0, \b PWM_INT_FAULT1, \b PWM_INT_FAULT2, and //! \b PWM_INT_FAULT3. //! //***************************************************************************** uint32_t PWMIntStatus(uint32_t ui32Base, bool bMasked) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); // // Read and return either the module's raw or enabled interrupt status. // if(bMasked == true) { return(HWREG(ui32Base + PWM_O_ISC)); } else { return(HWREG(ui32Base + PWM_O_RIS)); } } //***************************************************************************** // //! Clears the fault interrupt for a PWM module. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32FaultInts specifies the fault interrupts to clear. //! //! This function clears one or more fault interrupts by writing to the //! appropriate bit of the PWM interrupt status register. The parameter //! \e ui32FaultInts must be the logical OR of any of \b PWM_INT_FAULT0, //! \b PWM_INT_FAULT1, \b PWM_INT_FAULT2, or \b PWM_INT_FAULT3. //! //! The fault interrupts are derived by performing a logical OR of each of the //! configured fault trigger signals for a given generator. Therefore, these //! interrupts are not directly related to the four possible FAULTn inputs to //! the device but indicate that a fault has been signaled to one of the four //! possible PWM generators. //! //! \note Because there is a write buffer in the Cortex-M processor, it may //! take several clock cycles before the interrupt source is actually cleared. //! Therefore, it is recommended that the interrupt source be cleared early in //! the interrupt handler (as opposed to the very last action) to avoid //! returning from the interrupt handler before the interrupt source is //! actually cleared. Failure to do so may result in the interrupt handler //! being immediately reentered (because the interrupt controller still sees //! the interrupt source asserted). //! //! \return None. // //***************************************************************************** void PWMFaultIntClearExt(uint32_t ui32Base, uint32_t ui32FaultInts) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT((ui32FaultInts & ~(PWM_INT_FAULT0 | PWM_INT_FAULT1 | PWM_INT_FAULT2 | PWM_INT_FAULT3)) == 0); // // Clear the supplied fault bits. // HWREG(ui32Base + PWM_O_ISC) = ui32FaultInts; } //***************************************************************************** // //! Configures the minimum fault period and fault pin senses for a given //! PWM generator. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator for which fault configuration is being //! set. This function must be one of \b PWM_GEN_0, \b PWM_GEN_1, //! \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32MinFaultPeriod is the minimum fault active period expressed in //! PWM clock cycles. //! \param ui32FaultSenses indicates which sense of each FAULT input should be //! considered the ``asserted'' state. Valid values are logical OR //! combinations of \b PWM_FAULTn_SENSE_HIGH and \b PWM_FAULTn_SENSE_LOW. //! //! This function configures the minimum fault period for a given generator //! along with the sense of each of the 4 possible fault inputs. The minimum //! fault period is expressed in PWM clock cycles and takes effect only if //! PWMGenConfigure() is called with flag \b PWM_GEN_MODE_FAULT_PER set in the //! \e ui32Config parameter. When a fault input is asserted, the minimum fault //! period timer ensures that it remains asserted for at least the number of //! clock cycles specified. //! //! \note This function is only available on devices supporting extended PWM //! fault handling. //! //! \return None. // //***************************************************************************** void PWMGenFaultConfigure(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32MinFaultPeriod, uint32_t ui32FaultSenses) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT(ui32MinFaultPeriod < PWM_X_MINFLTPER_M); ASSERT((ui32FaultSenses & ~(PWM_FAULT0_SENSE_HIGH | PWM_FAULT0_SENSE_LOW | PWM_FAULT1_SENSE_HIGH | PWM_FAULT1_SENSE_LOW | PWM_FAULT2_SENSE_HIGH | PWM_FAULT2_SENSE_LOW | PWM_FAULT3_SENSE_HIGH | PWM_FAULT3_SENSE_LOW)) == 0); // // Write the minimum fault period. // HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_MINFLTPER) = ui32MinFaultPeriod; // // Write the fault senses. // HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSEN) = ui32FaultSenses; } //***************************************************************************** // //! Configures the set of fault triggers for a given PWM generator. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator for which fault triggers are being set. //! This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or //! \b PWM_GEN_3. //! \param ui32Group indicates the subset of possible faults that are to be //! configured. This parameter must be \b PWM_FAULT_GROUP_0 or //! \b PWM_FAULT_GROUP_1. //! \param ui32FaultTriggers defines the set of inputs that are to contribute //! towards generation of the fault signal to the given PWM generator. For //! \b PWM_FAULT_GROUP_0, this is the logical OR of \b PWM_FAULT_FAULT0, //! \b PWM_FAULT_FAULT1, \b PWM_FAULT_FAULT2, or \b PWM_FAULT_FAULT3. For //! \b PWM_FAULT_GROUP_1, this is the logical OR of \b PWM_FAULT_DCMP0, //! \b PWM_FAULT_DCMP1, \b PWM_FAULT_DCMP2, \b PWM_FAULT_DCMP3, //! \b PWM_FAULT_DCMP4, \b PWM_FAULT_DCMP5, \b PWM_FAULT_DCMP6, or //! \b PWM_FAULT_DCMP7. //! //! This function allows selection of the set of fault inputs that is combined //! to generate a fault condition to a given PWM generator. By default, all //! generators use only FAULT0 (for backwards compatibility) but if //! PWMGenConfigure() is called with flag \b PWM_GEN_MODE_FAULT_SRC in the //! \e ui32Config parameter, extended fault handling is enabled and this //! function must be called to configure the fault triggers. //! //! The fault signal to the PWM generator is generated by ORing together each //! of the signals specified in the \e ui32FaultTriggers parameter after having //! adjusted the sense of each FAULTn input based on the configuration //! previously set using a call to PWMGenFaultConfigure(). //! //! \note This function is only available on devices supporting extended PWM //! fault handling. //! //! \return None. // //***************************************************************************** void PWMGenFaultTriggerSet(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Group, uint32_t ui32FaultTriggers) { // // Check for valid parameters. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT((ui32Group == PWM_FAULT_GROUP_0) || (ui32Group == PWM_FAULT_GROUP_1)); ASSERT((ui32Group == PWM_FAULT_GROUP_0) && ((ui32FaultTriggers & ~(PWM_FAULT_FAULT0 | PWM_FAULT_FAULT1 | PWM_FAULT_FAULT2 | PWM_FAULT_FAULT3)) == 0)); ASSERT((ui32Group == PWM_FAULT_GROUP_1) && ((ui32FaultTriggers & ~(PWM_FAULT_DCMP0 | PWM_FAULT_DCMP1 | PWM_FAULT_DCMP2 | PWM_FAULT_DCMP3 | PWM_FAULT_DCMP4 | PWM_FAULT_DCMP5 | PWM_FAULT_DCMP6 | PWM_FAULT_DCMP7)) == 0)); // // Write the fault triggers to the appropriate register. // if(ui32Group == PWM_FAULT_GROUP_0) { HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC0) = ui32FaultTriggers; } else { HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC1) = ui32FaultTriggers; } } //***************************************************************************** // //! Returns the set of fault triggers currently configured for a given PWM //! generator. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator for which fault triggers are being //! queried. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1, //! \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32Group indicates the subset of faults that are being queried. //! This parameter must be \b PWM_FAULT_GROUP_0 or \b PWM_FAULT_GROUP_1. //! //! This function allows an application to query the current set of inputs that //! contribute to the generation of a fault condition to a given PWM generator. //! //! \note This function is only available on devices supporting extended PWM //! fault handling. //! //! \return Returns the current fault triggers configured for the fault group //! provided. For \b PWM_FAULT_GROUP_0, the returned value is a logical OR of //! \b PWM_FAULT_FAULT0, \b PWM_FAULT_FAULT1, \b PWM_FAULT_FAULT2, or //! \b PWM_FAULT_FAULT3. For \b PWM_FAULT_GROUP_1, the return value is the //! logical OR of \b PWM_FAULT_DCMP0, \b PWM_FAULT_DCMP1, //! \b PWM_FAULT_DCMP2, \b PWM_FAULT_DCMP3, \b PWM_FAULT_DCMP4, //! \b PWM_FAULT_DCMP5, \b PWM_FAULT_DCMP6, or \b PWM_FAULT_DCMP7. // //***************************************************************************** uint32_t PWMGenFaultTriggerGet(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Group) { // // Check for valid parameters. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT((ui32Group == PWM_FAULT_GROUP_0) || (ui32Group == PWM_FAULT_GROUP_1)); // // Return the current fault triggers. // if(ui32Group == PWM_FAULT_GROUP_0) { return(HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC0)); } else { return(HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC1)); } } //***************************************************************************** // //! Returns the current state of the fault triggers for a given PWM generator. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator for which fault trigger states are //! being queried. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1, //! \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32Group indicates the subset of faults that are being queried. //! This parameter must be \b PWM_FAULT_GROUP_0 or \b PWM_FAULT_GROUP_1. //! //! This function allows an application to query the current state of each of //! the fault trigger inputs to a given PWM generator. The current state of //! each fault trigger input is returned unless PWMGenConfigure() has //! previously been called with flag \b PWM_GEN_MODE_FAULT_LATCHED in the //! \e ui32Config parameter, in which case the returned status is the latched //! fault trigger status. //! //! If latched faults are configured, the application must call //! PWMGenFaultClear() to clear each trigger. //! //! \note This function is only available on devices supporting extended PWM //! fault handling. //! //! \return Returns the current state of the fault triggers for the given PWM //! generator. A set bit indicates that the associated trigger is active. //! For \b PWM_FAULT_GROUP_0, the returned value is a logical OR of //! \b PWM_FAULT_FAULT0, \b PWM_FAULT_FAULT1, \b PWM_FAULT_FAULT2, or //! \b PWM_FAULT_FAULT3. For \b PWM_FAULT_GROUP_1, the return value is the //! logical OR of \b PWM_FAULT_DCMP0, \b PWM_FAULT_DCMP1, //! \b PWM_FAULT_DCMP2, \b PWM_FAULT_DCMP3, \b PWM_FAULT_DCMP4, //! \b PWM_FAULT_DCMP5, \b PWM_FAULT_DCMP6, or \b PWM_FAULT_DCMP7. // //***************************************************************************** uint32_t PWMGenFaultStatus(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Group) { // // Check for valid parameters. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT((ui32Group == PWM_FAULT_GROUP_0) || (ui32Group == PWM_FAULT_GROUP_1)); // // Return the current fault status. // if(ui32Group == PWM_FAULT_GROUP_0) { return(HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT0)); } else { return(HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT1)); } } //***************************************************************************** // //! Clears one or more latched fault triggers for a given PWM generator. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Gen is the PWM generator for which fault trigger states are //! being queried. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1, //! \b PWM_GEN_2, or \b PWM_GEN_3. //! \param ui32Group indicates the subset of faults that are being queried. //! This parameter must be \b PWM_FAULT_GROUP_0 or \b PWM_FAULT_GROUP_1. //! \param ui32FaultTriggers is the set of fault triggers which are to be //! cleared. //! //! This function allows an application to clear the fault triggers for a //! given PWM generator. This function is only required if PWMGenConfigure() //! has previously been called with flag \b PWM_GEN_MODE_FAULT_LATCHED in //! parameter \e ui32Config. //! //! \note This function is only available on devices supporting extended PWM //! fault handling. //! //! \return None. // //***************************************************************************** void PWMGenFaultClear(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Group, uint32_t ui32FaultTriggers) { // // Check for valid parameters. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(_PWMGenValid(ui32Gen)); ASSERT((ui32Group == PWM_FAULT_GROUP_0) || (ui32Group == PWM_FAULT_GROUP_1)); ASSERT((ui32Group == PWM_FAULT_GROUP_0) && ((ui32FaultTriggers & ~(PWM_FAULT_FAULT0 | PWM_FAULT_FAULT1 | PWM_FAULT_FAULT2 | PWM_FAULT_FAULT3)) == 0)); ASSERT((ui32Group == PWM_FAULT_GROUP_1) && ((ui32FaultTriggers & ~(PWM_FAULT_DCMP0 | PWM_FAULT_DCMP1 | PWM_FAULT_DCMP2 | PWM_FAULT_DCMP3 | PWM_FAULT_DCMP4 | PWM_FAULT_DCMP5 | PWM_FAULT_DCMP6 | PWM_FAULT_DCMP7)) == 0)); // // Clear the given faults. // if(ui32Group == PWM_FAULT_GROUP_0) { HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT0) = ui32FaultTriggers; } else { HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT1) = ui32FaultTriggers; } } //***************************************************************************** /// //! Sets the PWM clock configuration. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32Config is the configuration for the PWM clock; it must be one of //! \b PWM_SYSCLK_DIV_1, \b PWM_SYSCLK_DIV_2, \b PWM_SYSCLK_DIV_4, //! \b PWM_SYSCLK_DIV_8, \b PWM_SYSCLK_DIV_16, \b PWM_SYSCLK_DIV_32, or //! \b PWM_SYSCLK_DIV_64. //! //! This function sets the PWM clock divider as the PWM clock source. It also //! configures the clock frequency to the PWM module as a division of the //! system clock. This clock is used by the PWM module to generate PWM //! signals; its rate forms the basis for all PWM signals. //! //! \note This function should not be used with TM4C123 devices. For //! TM4C123 devices, the SysCtlPWMClockGet() function should be used. //! //! \note The clocking of the PWM is dependent upon the system clock rate as //! configured by SysCtlClockFreqSet(). //! //! \return None. // //***************************************************************************** void PWMClockSet(uint32_t ui32Base, uint32_t ui32Config) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT((ui32Config == PWM_SYSCLK_DIV_2) || (ui32Config == PWM_SYSCLK_DIV_4) || (ui32Config == PWM_SYSCLK_DIV_8) || (ui32Config == PWM_SYSCLK_DIV_16) || (ui32Config == PWM_SYSCLK_DIV_32) || (ui32Config == PWM_SYSCLK_DIV_64)); // // Set the PWM clock configuration into the PWM clock configuration // register. // HWREG(ui32Base + PWM_O_CC) = ((HWREG(ui32Base + PWM_O_CC) & ~(PWM_CC_USEPWM | PWM_CC_PWMDIV_M)) | ui32Config); } //***************************************************************************** // //! Gets the current PWM clock configuration. //! //! \param ui32Base is the base address of the PWM module. //! //! This function returns the current PWM clock configuration. //! //! \note This function should not be used with TM4C123 devices. For //! TM4C123 devices, the SysCtlPWMClockGet() function should be used. //! //! \return Returns the current PWM clock configuration; is one of //! \b PWM_SYSCLK_DIV_1, \b PWM_SYSCLK_DIV_2, \b PWM_SYSCLK_DIV_4, //! \b PWM_SYSCLK_DIV_8, \b PWM_SYSCLK_DIV_16, \b PWM_SYSCLK_DIV_32, //! or \b PWM_SYSCLK_DIV_64. // //***************************************************************************** uint32_t PWMClockGet(uint32_t ui32Base) { // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); // // Return the current PWM clock configuration. Make sure that // PWM_SYSCLK_DIV_1 is returned in all cases where the divider is disabled. // if(!(HWREG(ui32Base + PWM_O_CC) & PWM_CC_USEPWM)) { // // The divider is not active so reflect this in the value we return. // return(PWM_SYSCLK_DIV_1); } else { // // The divider is active so directly return the masked register value. // return(HWREG(ui32Base + PWM_O_CC) & (PWM_CC_USEPWM | PWM_CC_PWMDIV_M)); } } //***************************************************************************** // //! Sets the update mode or synchronization mode to the PWM outputs. //! //! \param ui32Base is the base address of the PWM module. //! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter //! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT, //! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT, //! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT. //! \param ui32Mode specifies the enable update mode to use when enabling or //! disabling PWM outputs. //! //! This function sets one of three possible update modes to enable or disable //! the requested PWM outputs. The \e ui32Mode parameter controls when changes //! made via calls to PWMOutputState() take effect. Possible values are: //! //! - \b PWM_OUTPUT_MODE_NO_SYNC, which enables/disables changes to take effect //! immediately. //! - \b PWM_OUTPUT_MODE_SYNC_LOCAL, which causes changes to take effect when //! the local PWM generator's count next reaches 0. //! - \b PWM_OUTPUT_MODE_SYNC_GLOBAL, which causes changes to take effect when //! the local PWM generator's count next reaches 0 following a call to //! PWMSyncUpdate() which specifies the same generator in its \e ui32GenBits //! parameter. //! //! \note This function is only available on Snowflake class devices. //! //! \return None. // //***************************************************************************** void PWMOutputUpdateMode(uint32_t ui32Base, uint32_t ui32PWMOutBits, uint32_t ui32Mode) { uint_fast8_t ui8Index; uint32_t ui32PWMOutputMask; uint32_t ui32UpdateValueMask; uint32_t ui32UpdateValue; uint32_t ui32Temp; // // Check the arguments. // ASSERT((ui32Base == PWM0_BASE) || (ui32Base == PWM1_BASE)); ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT | PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT | PWM_OUT_6_BIT | PWM_OUT_7_BIT))); ASSERT((ui32Mode == PWM_OUTPUT_MODE_NO_SYNC) || (ui32Mode == PWM_OUTPUT_MODE_SYNC_LOCAL) || (ui32Mode == PWM_OUTPUT_MODE_SYNC_GLOBAL)); // // Initialize the local variables // ui8Index = 0; ui32PWMOutputMask = 1; ui32UpdateValue = 0; ui32UpdateValueMask = 0; // // Loop to find out which PWM outputs are to be modified. // while(ui8Index < 8) { // // Check if this PWM output is to be modified. // if(ui32PWMOutputMask & ui32PWMOutBits) { // // Set the update mode value for the requested PWM output by // writing to the appropriate field. // ui32UpdateValue |= ui32Mode << (ui8Index * 2); // // Compute the mask for the bits to be updated. // ui32UpdateValueMask |= 3 << (ui8Index * 2); } // // Update the PWM output to be checked and the index. // ui32PWMOutputMask = ui32PWMOutputMask << 1; ui8Index++; } // // Read the Enable Update register and mask the bits that are to be // updated. // ui32Temp = ~ui32UpdateValueMask & HWREG(ui32Base + PWM_O_ENUPD); // // Write the updated values to Enable Update register. // HWREG(ui32Base + PWM_O_ENUPD) = ui32Temp | ui32UpdateValue; } //***************************************************************************** // // Close the Doxygen group. //! @} // //*****************************************************************************